Automatic 4-Channel Vibratory Tablet Counter for Chlorine Tablets
4-Channel Vibratory Tablet Counter for Chlorine Tablets
This vibratory tablet counter is designed for accurate counting of chlorine tablets and chemical tablets in automated packaging lines.Ideal for chlorine tablet packaging and pool chemical tablet counting applications.
Accurate counting of chlorine and chemical tablets for automated packaging lines
- 4-channel vibratory tablet feeding system
- Suitable for chlorine and chemical tablets
- Corrosion-resistant PVC structure
- Adjustable counting range (1โ1000 pcs)
- Stable and continuous bottle discharge
- Easy mold replacement for different tablet sizes
- 4-channel vibratory tablet feeding
- Chlorine & chemical tablets
- Corrosion-resistant PVC structure
- Counting range: 1โ1000 pcs
- Stable, continuous bottle discharge
- Quick mold change for different sizes
Counting Range
Tablet Diameter
Output Speed
Control Method
Explore Other Tablet Counting Machines
Explore other tablet counter machines designed for different tablet sizes, counting channels, and production capacities.
Explore tablet counters for different tablet sizes and channels
Technical Specifications of the 4-Channel Vibratory Tablet Counter
The 4-channel vibratory tablet counter is designed for accurate counting and bottling of chlorine tablets, pool disinfection tablets, and other chemical tablets in automated packaging lines.
Key technical specifications of the 4-channel vibratory tablet counter designed for chlorine tablets and chemical tablet counting applications.
Technical Specifications
- Counting Type: 4-Channel Vibratory Counting
- Feeding System: Independent Vibratory Channels
- Applicable Tablet Size: 1.5โ35 mm
- Output Capacity: 40โ80 bottles/min
- Counting Range: 1โ1000 pcs/bottle (adjustable)
- Control Method: PLC + Touchscreen
- Feeding System๏ผ 4-Channel Vibratory Feeding System
- Anti-Corrosion Design๏ผChemical-resistant contact parts for chlorine tablets
- Power Supply: 220V / 380V, 50/60Hz
- Air Supply: 0.6 MPa
All specifications can be customized according to tablet size and production capacity requirements.
Technical Specifications
- Counting: 4-channel vibratory
- Feeding: Independent vibratory channels
- Tablet size: 1.5โ35 mm
- Speed: 40โ80 bottles/min
- Range: 1โ1000 pcs/bottle
- Control: PLC + Touchscreen
- Anti-corrosion: Chemical-resistant contact parts
- Power: 220V / 380V, 50/60Hz
- Air Supply: 0.6 MPa
All specifications can be customized according to tablet size and production capacity requirements.
Core Components of the Vibratory Tablet Counter
Vibratory feeding for accurate chlorine & chemical tablet counting ยท no sensors
Application: Chlorine ยท Pool ยท Chemical tablets
Key Features and Working Principle of the 4-Channel Vibratory Tablet Counter
- 4-channel independent vibratory feeding system
- Accurate mechanical tablet counting without optical sensors
- Suitable for chlorine tablets and chemical tablets
- Adjustable counting range for different packaging requirements
- Stable and continuous tablet feeding and bottle discharge
- Corrosion-resistant contact parts for chlorine tablets
- 4-channel independent vibratory feeding
- Mechanical counting ยท no optical sensors
- Chlorine & chemical tablets
- Counting range ยท adjustable
- Stable feeding & bottle discharge
- Corrosion-resistant contact parts
How the Vibratory Tablet Counter Works
In the vibratory tablet counter, tablets are fed through independent vibratory channels and guided into precision counting plates. The mechanical counting system allows tablets to pass through preset holes on the template plate, ensuring accurate counting before being discharged into bottles.
This mechanical counting principle ensures stable and reliable tablet counting performance without relying on optical sensors, making it suitable for chlorine tablets and corrosive chemical tablets.
Tablets are fed through independent vibratory channels into counting plates for accurate counting and discharge.
Mechanical counting without optical sensors ensures stable performance for chlorine and chemical tablets.
Why Choose Our Vibratory Tablet Counter for Chlorine Tablets?
Designed for stable and accurate counting of chlorine tablets using a precision vibratory tablet counter system.
Stable, accurate counting of chlorine tablets with vibratory tablet counter
4-Channel Feeding
Anti-Corrosion Design
Adjustable System
Stainless Steel Structure
Applications of the Vibratory Tablet Counter
The vibratory tablet counter is designed for accurate counting of chlorine and chemical tablets in automated packaging lines.
Accurate counting of chlorine and chemical tablets for automated packaging lines
Chlorine Tablet Manufacturers
Accurate counting solutions for pool chlorine tablet manufacturers.
Water Treatment Industry
Reliable counting for water treatment and disinfection tablets.
Cleaning & Chemical Products
Efficient counting for chemical cleaning and disinfection tablets.
Frequently Asked Questions
What tablets can the vibratory tablet counter handle?
The vibratory tablet counter is designed for counting chlorine tablets, pool disinfection tablets, chemical cleaning tablets, and other solid tablets used in industrial packaging lines.
What is the output capacity of the 4-channel tablet counter?
The standard output capacity ranges from 40 to 80 bottles per minute depending on tablet size, bottle size, and production conditions.
What tablet sizes are suitable for this counting machine?
This tablet counting machine is suitable for tablets with diameters from 1.5 mm to 35 mm, including chlorine tablets and other chemical tablets.
Does the machine use optical sensors for counting?
No. This vibratory tablet counter uses a mechanical counting system with precision counting plates, which provides stable performance without relying on optical sensors.
Is the tablet counting machine resistant to corrosion?
Yes. The machine is designed with corrosion-resistant contact parts suitable for chlorine tablets and other chemical products.
The 4-channel vibratory tablet counter ensures stable, accurate, and continuous tablet counting performance for chlorine and chemical tablet packaging lines.
Explore Other Vibratory Tablet Counter Models
๐น 2-Channel Model
Cost-effective tablet counting solution for small and medium production lines.
๐น 4-Channel Model
High-capacity vibratory tablet counting solution for large production lines.
Get the Right Vibratory Tablet Counter for Your Production Line
Tell us your tablet size, bottle size, and required production capacity.
Our engineers will recommend the most suitable vibratory tablet counter for your packaging line.
Pharmaceutical GMP Industry Standards
This anti-corrosive 4-channel tablet counting machine is designed in accordance with GMP standards, ensuring accurate and stable counting performance.
For general reference on GMP standards, you may refer to relevant industry guidelines.
Widely used in pharmaceutical and chemical production lines for precise counting of tablets, capsules, and small solid products.
Built to meet GMP standards for hygienic, reliable production.